Pharma Isolators

Isolators work under the principle of particle filtration, air recirculation and keeping work chamber at positive or negative pressure. In positive pressure isolators, 90% (±%5) of total internal air is recirculated passing through main HEPA/ULPA filter located at work zone top. The rest of the air is exhausted after passing through the HEPA/ULPA filter located at the top of the cabinet. Negative pressure isolators exhaust total cabinet air completely to the outer atmosphere without recirculation after passing through main filters. Pre/HEPA filtered room air is intaken by the top of the cabinet and pass-box provides the work area protecting the work zone under ISO-5 class laminar airflow. In addition to the primary air barrier accomplished by within the working zone double wall negative plenum design of the Metisafe cabinet prevents particle escape to surroundings and zero leakage is ensured.

Main Body & Design
  • Antibacterial epoxy powder paint coated stainless steel
  • 70 sloped front panel for comfort and work-chamber vision
  • Isolated automation systems from work-chamber
  • Interlocked ISO-5 dynamic pass-box with sliding tray
  • UV resistant safe front glass
  • Rounded cornered pass-box door glasses 
  • Leak-proof 0,6> mm chemical resistant gloves
Decontamination System
  • Single touch button full automatic decontamination process
  • Coordinated run with work-chamber temperature and humidity rates
  • Integrated H2O2 pulverization
  • Sensitive H2O2 measurement
  • Timer controlled efficient UV disinfection
Microprocessor Control Unit 
  • Wide display touch-screen
  • Air Velocity / Airflow Rate
  • Password protection
  • Normal/Stand-by work mode option
  • HEPA Filter Life, filter integrity status
  • Alarm activation log data
  • Work-chamber temperature and humidity rates
  • Illumination level adjustment
  • Online particle count data (optional)
  • Automatic decontamination process follow-up
  • UV and FL Lamp work times
  • UV lamp timer setting
Audio-Visual Alarm
  • System Ready/Not-Ready warning
  • Improper Air Flow/Rate warning
  • Decontamination error warning
  • Service need warning
  • Alarm cancel button
  • Filter/Lamp replacement warning
Quality and Certificates
  • CE
  • Management certificate of ISO9001
  • Biological Safety Cabinets EN 12469
  • ISO 14644 Clean Room class compatibility
  • EN61010 Electrical and Electronic safety compatibility
  • Accredited test company validation guarantee
UV Lamp30 W Electrical
Internal Dimensions (WxLxH) mm1201x630x620
External Dimensions (WxLxH) mm1860x912x1760
Pass-Box Dimensions (WxLxH) mm454x566x410
Support Stand (WxLxH) mm1370x803x762
Work Table Height8550 mm
Work Chamber Pressure (Pa)+30 Pa / -30 Pa
Exhaust Air volume (m3/s)450 <
Downflow Air velocity (m/s)0.38 m/s ± %5
Filters (EN 1822)Main FilterH14 HEPA, 0,3 µm %99.995 < 
Exhaust FilterH14 HEPA, 0,3 µm %99.995 < 
Pre-FilterF5

Work Chamber Cleanroom Class

EN14644< ISO 5
FED209E< Class 100
  
Work BenchStandard304 Stainless Steel
Optional316L Stainless Steel
Noise LevelNormal Mode< 55 dB(A)
Std-by Mode< 50 dB(A)
Front Glass< 6 mm Laminated
Front Glass Gloves Port Quantity2
Work Chamber Illumination (Lux)850 – 1250 Lux
Power consumption (kW)Fan Filter Unit170 W
Illumination32 W
Electrical socket and current220-240 VAC / 16A
Supply Voltage / Frequency /Power / Current220-240 VAC / 16A
Pack/Palette Dimensions (WxLxH) mm2010x1350x2030
Weight (kg) w/o support stand377
Internal Dimensions (WxLxH) mm1506x630x620
External Dimensions (WxLxH) mm2165x912x1760
Pass-Box Dimensions (WxLxH) mm454x567x410
Support Stand (WxLxH) mm1675x803x762
Work Table Height855 mm
Work Chamber Pressure (Pa)+30 Pa / -30 Pa
Exhaust Air volume (m3/s)450 <
Downflow Air velocity (m/s)0.38 m/s ± %5
Filters (EN 1822)Main FilterH14 HEPA, 0,3 µm particle %99.995 <
Exhaust FilterH14 HEPA, 0,3 µm particle %99.995 <
Pre-FilterF5
Clean Area ClassEN14644< ISO 5
FED209E< Class 100
  
Work BenchStandard304 Stainless Steel
Optional316L Stainless Steel
Noise LevelNormal Mode< 58 dB(A)
Stand-by Mode< 50 dB(A)
Front Glass< 6 mm Lamine
Front Glass Gloves Port Quantity2
Work Chamber Illumination (Lux)850 – 1250 Lux
Power consumption (kW)Fan Filter Unit340 W
Illumination32 W
UV Lamp30 W
Electrical socket voltage and current220-240 VAC / 16A
Supply Voltage / Frequency /Power / Current220-240 VAC / 16A
Pack/Palette Dimensions (WxLxH) mm2315x1350x2030
Weight (kg) w/o support stand462