Class IIA BSC - E Series
Metisafe® biological safety cabinets recirculate 70% (-/+5%) of the device’s total air. After passing through the main HEPA/ULPA filter, the clean air flows down to the work chamber. The 30% (-/+5%) of the total air is exhausted out of the cabin after passing through the exhaust HEPA filter at the top of the device. The indoor environment’s intaken air is passed through the air grills in the front section of the workbench and directed to the fan unit. Those air barriers prevent the reach of dirty indoor air into the workbench. Both intaken and recirculated total air inside the device is collected in the fan section. Then it passes through the pre-filter (optional), main HEPA filter and laminarizator, and protects the work material by providing ISO-5 cleanliness class laminar airflow. The primary air barrier occurs in the work chamber and the negative plenum structure surrounding it. The air in the cabin is prevented from reaching the user, including possible accidents,and a zero leakage work station is provided.
Main Body and Design Features
- Main body from static powder coated on 304 stainless steel
- <7° angle back sloped front panel for work comfort and increased working chamber vision
- 36° openable front panel for easy working chamber cleaning
- Electronic control & electrical parts are protected by isolating from work chamber
- UV resistant glass
Microprocessor Control Unit
- Password protected user interface
- Device on/off button
- Standby/Normal modes operation indicator
- Motorized front window level adjustment and one-button automatic front window level adjustment
- UV and illumination lamp On/Off buttons
- Lux Adjustable Illumination
- Automatic switch to Standby mode and UV lamp operation when the windshield is closed
- User interface password change
- Password protected technical service maintenance/calibration
- Date and time information
- Cabinet information page
- Downflow/Inflow Air velocity rate
- Fan working capacity
- Fan working diagram
- UV lamp timer setting
- Cabinet,UV and illumination running times
Audio-Visual Warning System
- Audible visual alarm button and temporary mute
- Improper front window position warning
- Improper air velocity warning
- Filter and UV lamp replacement warning
- Technical service maintenance warning
- Fan error warning
Quality And Certifications
- CE
- Biological Safety Cabinets EN12469
- ISO9001-2015 Quality Management Certificate
- ISO14644 Cleanroom Class Compatibility
- EN61010 Electric and Electronic Safety Compatibility
- Accredited Testing Institution Validation Guarantee
Optionals
- MOP. FWS Front Window Motion Safety
- MOP.HTS Humidity/Temperature Sensor
- MOP.RES Remote Access
- MOP.CFL Carbon Filter
- MOP.FLT.EU4 Pre-Filter
- MOP.CFL.EU4 Active Carbon Impregnated Pre-filter
- MOP.FLT.ULP ULPA Filter
- MOP.MIE Microscope Entegration
- MOP.PMS Particle Measure System
- MOP.BWT Precision Balance with Vibration Damping Weighing Table
- MOP.WCS Working Cabinet Suspension Apparatus (IV Bar)
- MOP.MDS Manuel Decontamination System
- MOP.SDS Semi-Automatic Decontamination System
- MOP.CCP Canopy Connection
- MOP.PRPO Process Parameter Recording System
870x510x696
1020x745x1480
997x695x740
840 mm
≥ 0.40 m/s
0.25 - 0.50 m/s
H14 HEPA, 0,3 µm paticle %99.995 < filtration efficiency
304 Stainless Steel
316 Stainless Steel
≤ 65 dB
≥750 Lux
1250x598x614
1400x855x1450
1370x803x740
840 mm
≥ 0.40 m/s
0.25 - 0.50 m/s
H14 HEPA, 0,3 µm paticle %99.995 < filtration efficiency
304 Stainless Steel
316 Stainless Steel
< 65 dB
≥750 Lux
1480x510x696
1630x745x1480
1602x695x740
840 mm
≥ 0.40 m/s
0.25 - 0.50 m/s
H14 HEPA, 0,3 µm paticle %99.995 < filtration efficiency
304 Stainless Steel
316 Stainless Steel
< 65 dB
≥750 Lux
1785x510x696
1935x745x1470
1907x695x740
840 mm
≥ 0.40 m/s
0.25 - 0.50 m/s
H14 HEPA, 0,3 µm paticle %99.995 < filtration efficiency
304 Stainless Steel
316 Stainless Steel
< 65 dB
≥750 Lux